返回列表
  • MEH8-40M
  • MEH8-40M

MEH8-40M

MEH8-40M Modular Contactor (also known as analog contactors and architectural contactors) are mainly used in power systems with AC 50Hz/60Hz, rated working voltage up to 400V and rated working current up to 100A. They are used as remote switches and control circuits in AC-1 and AC-7a (non-inductive or low-inductive loads, resistance furnaces, household appliances and similar low-inductive loads). It can also be used to control the load of household motor. Modular Contactors cant't be used in break short-circuit currents, so appropriate short-circuit protective appliances (such as small circuit breakers) should be selected when using them. BCH8 Modular Contactor are mainly used in homes, hotels, apartments, office buildings, public buildings, shopping malls, gymnasiums and other places to achieve automatic control functions.
  • Product Description
  • Technical Data
  • Inquiry
  • Related Products

Product Description

MEH8-40M Modular Contactor (also known as analog contactors and architectural contactors) are mainly used in power systems with AC 50Hz/60Hz, rated working voltage up to 400V and rated working current up to 100A. They are used as remote switches and control circuits in AC-1 and AC-7a (non-inductive or low-inductive loads, resistance furnaces, household appliances and similar low-inductive loads). It can also be used to control the load of household motor. Modular Contactors cant't be used in break short-circuit currents, so appropriate short-circuit protective appliances (such as small circuit breakers) should be selected when using them. BCH8 Modular Contactor are mainly used in homes, hotels, apartments, office buildings, public buildings, shopping malls, gymnasiums and other places to achieve automatic control functions.

Technical Data

Product nameModular ContactorRated controlling power supply voltage UsAC 24/50Hz AC230/50Hz
Model No.MEH8-40MElectrical life10000times
Rated currents

16,20,25,40,63,100A(AC-7a);

6,7,8.5,15,20,30A(AC-7b)

Mechanical life100000times
Rated frequency
50Hz/60HzMaximum switching operations per hour30times
Conventional thermal current25,25,25,63,63,100AMaximum switching operations per day100times
Rated insulation voltage 500V
Pollution degree 
2
Rated operation voltage 
250V(1P/2P) 400V(3P/4P)Protection degree Enclosure:IP20
Installed in distri bution box:IP40
Rated impulse withstand voltage Uimp
2.5kV(4kV--12/24/48VAV)
Working temperature-5℃~ + 60℃

Inquiry

  • *
  • *
  • *